To a certain extent, the globe valve and the gate valve can be said to have many connections. Can it be said that the globe valve and the gate valve can actually be mixed? Shanghai Dongbao Valve Manufacturing Co., Ltd. is here to answer this question for you.
1. Structure
When the installation space is limited, please pay attention to the selection:
The gate valve can be tightly closed with the sealing surface depending on the medium pressure, so as to achieve the effect of no leakage. When opening and closing, the valve core and the valve seat sealing surface are always in contact and rub against each other, so the sealing surface is easy to wear. When the gate valve is close to closing, the pressure difference between the front and rear of the pipeline is large, which makes the sealing surface wear more serious.
The structure of the gate valve will be more complicated than the shut-off valve. From the appearance point of view, the gate valve is taller than the shut-off valve and the shut-off valve is longer than the gate valve in the case of the same caliber. In addition, the gate valve can be divided into bright rod and dark rod. The shut-off valve does not.
2. Working principle
When the shut-off valve is opened and closed, the stem rises, that is to say, when the hand wheel is turned, the hand wheel will rotate and lift together with the stem. The gate valve rotates the hand wheel to make the valve stem move up and down, and the position of the hand wheel remains unchanged.
The flow rate is different, the gate valve is required to be fully open or fully closed, but the stop valve is not required. The shut-off valve has specified inlet and outlet directions, and the gate valve has no inlet and outlet direction requirements.
In addition, the gate valve has only two states: fully open or fully closed, the gate opening and closing stroke is large, and the opening and closing time is long. The movement stroke of the valve plate of the shut-off valve is much smaller, and the valve plate of the shut-off valve can be stopped at a certain place during the movement for flow adjustment. The gate valve can only be used for cutting off, and has no other functions.
3. Performance difference
The shut-off valve can be used for cut-off and flow adjustment. The fluid resistance of the globe valve is relatively large, and it is more laborious to open and close, but because the distance between the valve plate and the sealing surface is short, the opening and closing stroke is short.
Because the gate valve can only be fully opened and fully closed, when it is fully opened, the medium flow resistance in the valve body channel is almost zero, so the opening and closing of the gate valve will be very labor-saving, but the gate is far away from the sealing surface and the opening and closing time is long. .
4. Installation and flow
The effect of the gate valve in both directions is the same. There is no requirement for the inlet and outlet directions for installation, and the medium can circulate in both directions. The shut-off valve needs to be installed in strict accordance with the direction of the arrow mark on the valve body. There is also a clear stipulation about the direction of the inlet and outlet of the shut-off valve. my country’s valve “Sanhua” stipulates that the flow direction of the shut-off valve shall be from top to bottom.
The shut-off valve is low in and high out. From the outside, it is obvious that the pipeline is not on the horizontal line of one phase. The gate valve flow path is on a horizontal line. The stroke of the gate valve is larger than that of the stop valve.
From the perspective of flow resistance, the flow resistance of the gate valve is small when fully opened, and the flow resistance of the load stop valve is large. The flow resistance coefficient of ordinary gate valve is about 0.08~0.12, the opening and closing force is small, and the medium can flow in two directions.
The flow resistance of ordinary shut-off valves is 3-5 times that of gate valves. When opening and closing, it needs to be forced to close to achieve the seal. The valve core of the stop valve does not contact the sealing surface when it is completely closed, so the wear of the sealing surface is very small. The stop valve that needs to add an actuator due to the main flow force should pay attention to the torque control mechanism Adjustment.
When the shut-off valve is installed, the medium can enter from below the valve core and enter from above in two ways.
The advantage of the medium entering from below the valve core is that the packing is not under pressure when the valve is closed, which can prolong the service life of the packing, and can replace the packing when the pipe in front of the valve is under pressure.
The disadvantage of the medium entering from the bottom of the valve core is that the driving torque of the valve is relatively large, about 1.05~1.08 times that of the above entering, the valve stem is subjected to large axial force, and the valve stem is easy to bend.
For this reason, the way that the medium enters from below is generally only suitable for small-diameter stop valves (below DN50). For stop valves above DN200, the medium enters from above. The electric shut-off valve generally adopts the way that the medium enters from above.
The disadvantage of the way the medium enters from above is just the opposite of the way the medium enters from below. In fact, it can flow in both directions, just considering different perspectives.
5. Seal
The sealing surface of the globe valve is a small trapezoidal side of the valve core (see the shape of the valve core for details). Once the valve core falls off, it is equivalent to closing the valve (if the pressure difference is large, of course the closing is not tight, but the anti-reverse effect is not bad). The gate valve is sealed by the side of the valve core gate plate, the sealing effect is not as good as the stop valve, and the valve core will not be closed like the stop valve when the valve core falls off.